Oil furnaces must be maintained consistently to ensure reliable performance. If your oil furnace Marietta, GA is not working properly it is likely your furnace needs service. Our heating service technicians have years of experience working on oil furnaces like yours in Marietta, GA. Swann Mechanical service vehicles are on call 24 hours per day are fully equipped with the tools and parts necessary to get your oil furnace back up and operating.

Our oil furnace repair, furnace service or replacement pricing is competitive. Our estimates are always firm with no hidden surprises. You can rely on Swann Mechanical to advise you properly and to do excellent work promptly.


1 system planned maintenance,furnace short cycling

Marietta, GA
01-22-2018


3 system heat check with dehumidifier

Marietta, GA
01-09-2018


3 system heat check with dehumidifier

Marietta, GA
01-09-2018


Heat maintenance

Marietta, GA
01-18-2017


3 system heat check with dehumidifier

Marietta, GA
01-09-2018


No heat

Marietta, GA
01-24-2018


No heat

Marietta, GA
01-24-2018


1. Checked/Changed filters. 2. Checked drain line and safety switch 3. Checked electrical breaker and connecti ons. 4. Checked blower motor amp draw & capacitor. 5. Checked heat strips operation. 6. Checked temperature rise & tested fan limit safety switch. 7.Checked thermostat in heat mode.bvv

Marietta, GA
02-06-2018


1. Checked/Changed filters. 2. Checked drain line and safety switch 3. Checked electrical breaker and connections. 4. Checked blower motor amp draw & capacitor. 5. Checked heat strips operation. 6. Checked temperature rise & tested fan limit safety switch. 7.Checked thermostat in heat mode.

Marietta, GA
01-31-2018


1. Checked/Changed filters. 2. Checked drain line and safety switch 3. Checked electrical breaker and connections. 4. Checked blower motor amp draw & capacitor. 5. Checked heat strips operation. 6. Checked temperature rise & tested fan limit safety switch. 7.Checked thermostat in heat mode.

Marietta, GA
01-31-2018


No heat

Marietta, GA
01-26-2018


Changed filters 2. Checked thermostat operation in heating mode 3. Cleaned flame sensor 4. Checked pressure switch 5. Clean inducer port and checked motor 6. Checked blower motor and capacitor 7. Checked heat rise across chambers 8. Checked flue and gas connections 9. Tested ingnitor Get Outlook

Marietta, GA
01-26-2018


1. Changed filters 2. Checked thermostat operation in heating mode 3. Cleaned flame sensor 4. Checked pressure switch 5. Clean inducer port and checked motor 6. Checked blower motor and capacitor 7. Checked heat rise across chambers 8. Checked flue and gas connections 9. Tested ingnitor

Marietta, GA
01-26-2018